Adhesive series
Model: JS-3450 Two-component Adhesive
Adhesive series
Model: JS-3450 Two-component Adhesive
Features:
I. Reference ratio: JS-3450 two-component glue component A: JS-3450 two-component glue component B = 8: 2.
2. Stir well.
3. Film thickness: 10 ± 1μm (determined according to different post-processing, application, and quality requirements of the film structure)
4. Hot air temperature: 80 ℃ -120 ℃ (reference value). After the solvent is evaporated, cover it again.
5. Covering drying tunnel temperature: 70-80 ℃ (reference value)
Six, ripening: left at 50 ℃ for more than 48 hours, at room temperature for more than 72 hours.
7. Activation time after mixing glue of component A and B: 3 hours. (Note: It is recommended to use up the glue with a good ratio within the activation time, otherwise the glue will gradually thicken, which will cause difficulties in construction and reduce performance. Therefore, pay attention to how much to use, otherwise it will waste if you use too much. )